MPX Series Magnetostrictive Level Sensors Rev. B, 4/13
22
Automation Products Group, Inc.
APG...Providing tailored solutions for measurement applications
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]
Applicaon Type 5: Volume of horizontal cylindrical tank with or without
hemispherical ends
Register Funcon Value Range
40402 Applicaon Type 5
40403 Volume Units 1 to 7
40404 Decimal Place 0 to 3
40406 Full Distance Typically = Blanking
40407 Empty Distance 0 to 10364 mm
40436-40437 Tank Length 0 to 100,000 mm
40438-40439 Tank Diameter 0 to 100,000 mm
40440-40441 End Radius 0 to 100,000 mm
Diameter
Length
Empty
Distance
End
Radius
Full
Distance